Real-Time Monitoring of the Polyethylene Microencapsulation of Low-Level Mixed Waste and Surrogates by Transient Infrared Spectroscopy

Thumbnail Image
Date
1996
Authors
Jones, Roger
McClelland, John
Weeks, Stephan
Faucette, Andrea
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Research Projects
Organizational Units
Organizational Unit
Ames National Laboratory

Ames National Laboratory is a government-owned, contractor-operated national laboratory of the U.S. Department of Energy (DOE), operated by and located on the campus of Iowa State University in Ames, Iowa.

For more than 70 years, the Ames National Laboratory has successfully partnered with Iowa State University, and is unique among the 17 DOE laboratories in that it is physically located on the campus of a major research university. Many of the scientists and administrators at the Laboratory also hold faculty positions at the University and the Laboratory has access to both undergraduate and graduate student talent.

Journal Issue
Is Version Of
Versions
Series
Department
Ames National Laboratory
Abstract

Rocky Flats Environmental Technology Site and other DOE sites have large volumes of low-level mixed waste (LLMW) in powdered forms, which must be processed into stable waste forms suitable for long-term storage. Polyethylene microencapsulation, in which the waste is thoroughly mixed with molten polyethylene and extruded into containers, is the first LLMW stabilization process that can be monitored in real-time to avoid processing errors and provide regulators with proof-of-proper-processing documentation. Monitoring compatibility and the smaller, lighter, more economical, inert polyethylene waste form results in significant advantages over cementation and grout based matrices, which are prone to chemical interaction with the waste. The monitor is a noncontact device that acquires the midinfrared spectrum of the process stream via emission spectroscopy. The stream composition is then derived from the spectrum using partial-least-squares techniques. Monitor operation is insensitive to the thickness of the process stream and to its surface morphology. The monitor has been demonstrated on polyethylene microencapsulation lines processing nitrate-salt LLMW and its surrogate, molten salt oxidation LLMW and its surrogate, and flyash. Typically, the monitor achieves a standard error of prediction of less than 1% by weight with an analysis time of less than 20 seconds.

Comments

This proceedings is from Waste Management '96 (1996): 613-619. Posted with permission.