Gas Holdup in Opaque Cellulose Fiber Slurries

Thumbnail Image
Date
2005-06-01
Authors
Talcott, Sarah
Heindel, Theodore
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Heindel, Theodore
University Professor
Research Projects
Organizational Units
Organizational Unit
Mechanical Engineering
The Department of Mechanical Engineering at Iowa State University is where innovation thrives and the impossible is made possible. This is where your passion for problem-solving and hands-on learning can make a real difference in our world. Whether you’re helping improve the environment, creating safer automobiles, or advancing medical technologies, and athletic performance, the Department of Mechanical Engineering gives you the tools and talent to blaze your own trail to an amazing career.
Journal Issue
Is Version Of
Versions
Series
Department
Mechanical Engineering
Abstract

Three different cellulose fiber types are used to study their effect on gas holdup and flow regime transition in a 10.2 cm semi-batch bubble column. The three natural fiber types include bleached softwood chemical pulp (softwood), bleached hardwood chemical pulp (hardwood), and bleached softwood chemithermomechanical pulp (BCTMP). Gas holdup is recorded over a range of fiber mass fractions (0 ≤ C ≤ 1.6%) and superficial gas velocities (Ug ≤ 23 cm/s). Experimental results show that gas holdup decreases with increasing fiber mass fraction. Homogeneous, transitional, and heterogeneous flow is observed for all three fiber types at low fiber mass fractions. All three fiber types produce similar results in the homogeneous flow regime while significant differences are recorded in the heterogeneous flow regime; those being low mass fraction hardwood (softwood) fiber slurries produce the highest (lowest) gas holdup. At higher fiber mass fractions, only pure heterogeneous flow is observed and softwood fiber slurries still produce the lowest gas holdup, although the differences in gas holdup between fiber types are small. The Zuber-Findlay drift flux model is used to describe the gas holdup results in cellulose fiber slurries when the flow conditions are heterogeneous. The Zuber-Findlay drift flux model is also used to identify the superficial gas velocity at which homogeneous flow is no longer observed with some success. Generally, the superficial gas velocity at which the flow deviates from homogeneous flow decreases with increasing fiber mass fraction.

Comments

This is a conference proceeding from ASME 2005 Fluids Engineering Division Summer Meeting 1 (2005): 43, doi:10.1115/FEDSM2005-77043. Posted with permission.

Description
Keywords
Citation
DOI
Copyright
Sat Jan 01 00:00:00 UTC 2005