A Simplified Turbulence Model for Describing Airflow in Ceiling Slot-ventilated Enclosures

Thumbnail Image
Date
1995
Authors
Hoff, Steven
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Hoff, Steven
Professor Emeritus
Research Projects
Organizational Units
Journal Issue
Is Version Of
Versions
Series
Department
Agricultural and Biosystems Engineering
Abstract

A numerical model was developed to predict flow occurring with opposing plane-wall ceiling jets representative of slot-ventilated livestock facilities. This model, termed the BETA model, was evaluated by comparing predicted axial and animal occupied zone (AOZ) velocity distributions with a low Reynold’s Number turbulence model (LBLR) and a laminar model (LAM). In addition, the BETA model results were compared with experimental results from a laboratory-scale test chamber. For opposing plane-wall ceiling jets, the predominant gradient in turbulent viscosity was predicted to occur in the vertical direction. An effective viscosity was defined as a function of the inlet Reynold’s Number (ReH) and normalized vertical height from the floor. The effective viscosity was used to selectively augment the laminar viscosity in the Navier-Stoke’s equation. Predicted comparisons between BETA and the LBLR models showed negligible differences for ventilating conditions between ReH of 35,032 and 11,752. Comparison with experimentally measured axial velocity decay indicated that the BETA model reproduced ceiling jet development as well as the LBLR model.

Comments

This article is from Transactions of the ASAE 38, no. 6 (1005): 1853–1862.

Description
Keywords
Citation
DOI
Source
Copyright
Sun Jan 01 00:00:00 UTC 1995