Flow cytometry is a promising and rapid method for differentiating between freely suspended Escherichia coli and E. coli attached to clay particles

Thumbnail Image
Supplemental Files
Date
2014-12-01
Authors
Rigby, Shawn
Jarboe, Laura
Zhang, Wei
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Jarboe, Laura
Professor
Person
Soupir, Michelle
Associate Dean
Research Projects
Organizational Units
Journal Issue
Is Version Of
Versions
Series
Department
Agricultural and Biosystems EngineeringChemical and Biological Engineering
Abstract

Aim: A standard procedure does not exist to distinguish between attached and unattached micro-organisms. In this study, we compared two methods to quantify between Escherichia coli attached to clay particles and E. coli freely suspended in solution: flow cytometry (attachment assay and viability assay) and settling (or centrifugation followed by settling).

Methods and Results: Methods were tested using three environmental strains collected from swine facilities (A, B and C) and one purchased modified pathogenic strain (ATCC 43888); four clay particles: Hectorite, Kaolinite, Ca-Montmorillonite, Montmorillonite K-10; and a range of surface area ratios (particle surface area to E. coli surface area). When comparing the two methods, the per cent attached obtained from the flow cytometry was lower, but not significantly different from the per cent attached obtained from the settling method for all conditions except when the particle was Hectorite or Montmorillonite K-10; when the strain was C; and when the surface area ratio was below 100. Differences between the methods are likely because traditional culture-based methods cannot detect the viable but nonculturable (VBNC) population, whereas flow cytometry can detect the fraction of VBNC with intact membranes.

Conclusion: Our results indicate that flow cytometry is a rapid and culture-independent method for differentiating between attached and unattached micro-organisms.

Significance and Impact of the Study: Flow cytometry is useful for laboratory-based studies of micro-organism–particle interactions.

Comments

This is the peer reviewed version of the following article: Liang, X., Soupir, M. L., Rigby, S., Jarboe, L. R., and Zhang, W. (2014). Journal of Applied Microbiology 117, 1730–1739, which has been published in final form at http://dx.doi.org/ 10.1111/jam.12660. This article may be used for non-commercial purposed in accordance with Wiley Terms and Conditions for Self-Archiving.

Description
Keywords
Citation
DOI
Copyright
Wed Jan 01 00:00:00 UTC 2014
Collections