Vacuum-assisted sorbent extraction: An analytical methodology for the determination of ultraviolet filters in environmental samples

Thumbnail Image
Supplemental Files
Date
2020-02-01
Authors
Trujillo-Rodríguez, María
Anderson, Jared
Dunham, Sage
Noad, Victoria
Cardin, Daniel
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Research Projects
Organizational Units
Organizational Unit
Journal Issue
Is Version Of
Versions
Series
Department
Chemistry
Abstract

Vacuum-assisted sorbent extraction (VASE) has been applied for the first time in the determination of UV filters in water samples in combination with gas chromatography-mass spectrometry. VASE is a variant of headspace extraction which was developed in conjunction with the sorbent pen (SP) technology. This technique combines the advantages of both stir-bar assisted extraction and headspace solid-phase microextraction. The SP traps allowed both reduced pressure in-vial extraction and direct thermal desorption via a unique gas chromatographic injection port. The main parameters that affect the performance of VASE, including both extraction and desorption conditions, were extensively optimized. Under optimum conditions, extraction required 10 mL of sample within 40 mL vials, pH 3.5, ∼30 s of air-evacuation, 14 h incubation at 70 °C, stirring at 200 rpm, and a final water management step conducted at ∼ −17 °C for 15 min. Optimal thermal desorption required preheating at 260 °C for 2 min followed by desorption at 300 °C for 2 min. The beneficial effect of reduced-pressure extraction was demonstrated by comparing the UV filter extraction time profiles collected using VASE to an analogous atmospheric pressure procedure, resulting in up to a 3-fold improvement under optimized conditions. The VASE methodology enabled simultaneous extractions using different SPs without compromising the method reproducibility, which increases the overall sample throughput. The method was characterized by low limits of detection, from 0.5 to 80 ng L−1, and adequate reproducibility, with inter-SP and inter-day relative standard deviation lower than 14%. Tap and lake water was successfully analyzed with the proposed methodology, resulting in relative recoveries of spiked samples ranging between 70.0 and 120%.

Comments

This is a manuscript of an article published as Trujillo-Rodríguez, María J., Jared L. Anderson, Sage JB Dunham, Victoria L. Noad, and Daniel B. Cardin. "Vacuum-assisted sorbent extraction: An analytical methodology for the determination of ultraviolet filters in environmental samples." 208 Talanta (2019): 120390. DOI: 10.1016/j.talanta.2019.120390. Posted with permission.

Description
Keywords
Citation
DOI
Subject Categories
Copyright
Tue Jan 01 00:00:00 UTC 2019
Collections