Kinematic and Kinetic Indicators of Sit-to-Stand.

Thumbnail Image
Date
2016-02-01
Authors
Stevermer, Catherine
Gillette, Jason
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Gillette, Jason
Associate Professor
Research Projects
Organizational Units
Organizational Unit
Kinesiology
The Department of Kinesiology seeks to provide an ample knowledge of physical activity and active living to students both within and outside of the program; by providing knowledge of the role of movement and physical activity throughout the lifespan, it seeks to improve the lives of all members of the community. Its options for students enrolled in the department include: Athletic Training; Community and Public Health; Exercise Sciences; Pre-Health Professions; and Physical Education Teacher Licensure. The Department of Physical Education was founded in 1974 from the merger of the Department of Physical Education for Men and the Department of Physical Education for Women. In 1981 its name changed to the Department of Physical Education and Leisure Studies. In 1993 its name changed to the Department of Health and Human Performance. In 2007 its name changed to the Department of Kinesiology. Dates of Existence: 1974-present. Historical Names: Department of Physical Education (1974-1981), Department of Physical Education and Leisure Studies (1981-1993), Department of Health and Human Performance (1993-2007). Related Units: College of Human Sciences (parent college), College of Education (parent college, 1974 - 2005), Department of Physical Education for Women (predecessor) Department of Physical Education for Men
Journal Issue
Is Version Of
Versions
Series
Department
Kinesiology
Abstract

Variation in the timing indicators separating sit-to-stand (STS) into movement phases complicates both research comparisons and clinical applications. The purpose of this study was to use kinetic reference standards to identify accurate kinematic and kinetic indicators for STS movement analysis such that consistent indicators might be used for STS from varied initial postures. Healthy adults performed STS using 4 foot placements: foot-neutral, foot-back, right-staggered, and left-staggered. Kinetic and kinematic data were collected from force platforms and an 8-camera video system. Initiation, seat-off, vertical posture, and termination were detected with 5% start and 7.5% end thresholds for changes in kinetic and kinematic STS indicators. Timing differences between kinetic and kinematic indicator time points and the reference vertical seated reaction force end point (seatoff) were determined. Kinematic indicators were compared with selected kinetic indicators using timing differences, statistical similarity, and internal consistency measures. Our results suggest that a single force platform system measuring vertical GRF or a simple camera system to evaluate the shoulder marker position and velocity can accurately and consistently detect STS initiation, seat-off, and vertical posture. In addition, these suggested STS indicators for initiation, seat-off, and vertical posture were not dependent upon foot placement.

Comments

This is a accepted manuscript from Journal of Applied Biomachanics, 2016, 32(1); 7-15. DOI; 10.1123/jab.2014-0189. Posted with permission.

Description
Keywords
Citation
DOI
Copyright
Fri Jan 01 00:00:00 UTC 2016
Collections