Analysis of Different Methods to Compute Ammonia Concentration and Emission Rate

Thumbnail Image
Date
2008-08-01
Authors
Gates, Richard
Overhults, Douglas
Li, Hong
Burns, Robert
Xin, Hongwei
Earnest, John
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Person
Xin, Hongwei
Distinguished Professor Emeritus
Research Projects
Organizational Units
Organizational Unit
Agricultural and Biosystems Engineering

Since 1905, the Department of Agricultural Engineering, now the Department of Agricultural and Biosystems Engineering (ABE), has been a leader in providing engineering solutions to agricultural problems in the United States and the world. The department’s original mission was to mechanize agriculture. That mission has evolved to encompass a global view of the entire food production system–the wise management of natural resources in the production, processing, storage, handling, and use of food fiber and other biological products.

History
In 1905 Agricultural Engineering was recognized as a subdivision of the Department of Agronomy, and in 1907 it was recognized as a unique department. It was renamed the Department of Agricultural and Biosystems Engineering in 1990. The department merged with the Department of Industrial Education and Technology in 2004.

Dates of Existence
1905–present

Historical Names

  • Department of Agricultural Engineering (1907–1990)

Related Units

Journal Issue
Is Version Of
Versions
Series
Department
Agricultural and Biosystems Engineering
Abstract

This work evaluates a simple method to measure ammonia concentration average for building emissions measurements, using a low-cost system (Portable Monitoring Unit, PMU). The method is compared to a more sophisticated (Mobile Air Emission Monitoring Unit, MAEMU) as a standard. The research was conducted in two similar broiler houses in western Kentucky, USA. Four PMU monitors were randomly assigned to three locations in each broiler house in which simultaneous MAEMU measurements were being conducted as part of a year-long ammonia emissions project. The PMUs were configured to record data every 30s. Samples were taken from within the house for six minutes, followed by a fourteen-minute purge with outside air. Three different methods for computing 60-minute averages of ammonia concentration were evaluated based on the concentration readings taken from the PMU, considering that final concentration value and sampling intervals directly affect the computation of ammonia emission. The methods studied were denoted AVE2, AVE4 and MAX. The AVE2 method used values from the last two minutes of the sampling period, excluding the last value, whereas the AVE4 method used values from the middle four minutes of the sampling period, and the MAX method used the maximum concentration value over the sampling period. The MAEMU system obtained more frequent and accurate concentration and ER measurements (six to thirty measurements per location per hour). The three methods showed values very close to the standard results, and the method AVE 4 seems to be the more similar with MAEMU. The average differences between PMU AVE4 method and MAEMU are -1.06 ppm and -0.052 g/hr for NH3 concentration and emission rate, respectively, considering 20-minute averages. Results demonstrate the importance of careful selection of representative concentration readings when fans are operating, and the significant impact that different ventilation regimes can have on the accuracy.

Comments

This proceeding is from Pp 1-9 in Livestock Environment VIII, Proceedings of the International Symposium. (31 August – 4 September 2008, Iguassu Falls, Brazil) St. Joseph Michigan: ASABE, 31 August 2008. ASAE Pub #701P0408.

Description
Keywords
Citation
DOI
Source
Copyright
Tue Jan 01 00:00:00 UTC 2008