Evaluation of Ion-Selective Membranes for Real-Time Soil Nutrient Sensing

Thumbnail Image
Date
2003-07-01
Authors
Kim, Hak-Jin
Hummel, John
Birrell, Stuart
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Birrell, Stuart
Professor
Research Projects
Organizational Units
Organizational Unit
Agricultural and Biosystems Engineering

Since 1905, the Department of Agricultural Engineering, now the Department of Agricultural and Biosystems Engineering (ABE), has been a leader in providing engineering solutions to agricultural problems in the United States and the world. The department’s original mission was to mechanize agriculture. That mission has evolved to encompass a global view of the entire food production system–the wise management of natural resources in the production, processing, storage, handling, and use of food fiber and other biological products.

History
In 1905 Agricultural Engineering was recognized as a subdivision of the Department of Agronomy, and in 1907 it was recognized as a unique department. It was renamed the Department of Agricultural and Biosystems Engineering in 1990. The department merged with the Department of Industrial Education and Technology in 2004.

Dates of Existence
1905–present

Historical Names

  • Department of Agricultural Engineering (1907–1990)

Related Units

Journal Issue
Is Version Of
Versions
Series
Department
Agricultural and Biosystems Engineering
Abstract

A key to developing a real time, automated soil nutrient sensor depends on the ability to effectively extract soil nutrients from a soil sample and precisely detect them in a very short time period. An ion-selective field effect transistor (ISFET) chip has proven to be a good candidate for use in real-time soil nutrient sensing because of its rapid response and low sample volume. This paper describes the evaluation of nitrate ionselective membranes and the investigation of the interaction between the ion-selective membranes and soil extracting solutions. The response characteristics of the membranes and their suitability for use for real-time soil nutrient sensing were investigated through evaluation of their sensitivity and selectivity using 16 ion selective electrodes (ISEs) in a computer-controlled system. All membranes showed an approximately linear Nernstian response when nitrate concentrations were above 10-3 M, irrespective of extracting solution type. At low nitrate concentrations, below 10-4 M, both the extracting solution and ligand types significantly affected the sensitivity and selectivity of each membrane. A TDDA-NPOE membrane showed greater sensitivity to nitrate than did the MTDA-NPOE and MTDA-TOTM membranes. In addition, the selectivity of the TDDA membrane was superior to that of the MTDA membranes when bicarbonate, chloride, and bromide were considered as the interfering ions.

Comments

Works produced by employees of the U.S. Government as part of their official duties are not copyrighted within the U.S. The content of this document is not copyrighted.

Description
Keywords
Citation
DOI