Thermal Characteristics of a Hoop Structure for Swine Production

Thumbnail Image
Date
1997
Authors
Tanaka, Akihiro
Xin, Hongwei
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Xin, Hongwei
Distinguished Professor Emeritus
Research Projects
Organizational Units
Organizational Unit
Agricultural and Biosystems Engineering

Since 1905, the Department of Agricultural Engineering, now the Department of Agricultural and Biosystems Engineering (ABE), has been a leader in providing engineering solutions to agricultural problems in the United States and the world. The department’s original mission was to mechanize agriculture. That mission has evolved to encompass a global view of the entire food production system–the wise management of natural resources in the production, processing, storage, handling, and use of food fiber and other biological products.

History
In 1905 Agricultural Engineering was recognized as a subdivision of the Department of Agronomy, and in 1907 it was recognized as a unique department. It was renamed the Department of Agricultural and Biosystems Engineering in 1990. The department merged with the Department of Industrial Education and Technology in 2004.

Dates of Existence
1905–present

Historical Names

  • Department of Agricultural Engineering (1907–1990)

Related Units

Journal Issue
Is Version Of
Versions
Series
Department
Agricultural and Biosystems Engineering
Abstract

The thermal performance of a low-cost, hoop-type swine building (3.55 × 5.7 × 10.3 m) was evaluated under the winter weather conditions of Central Japan. The hoop building had two curved roofs made from 2.5 cm diameter tubular steel pipes each covered with a reflective film. There was a 20 cm air space between the inner and outer covers through which the exhaust air flowed. A positive-pressure ventilation fan and an air distribution duct were used to supply the fresh air. The evaluation was conducted for three opening configurations of the air distribution duct (one, two, or four holes on a cross-section of the duct) and presence or absence of an internal curtain. Furthermore, the effect of replacing the reflective film with a PVC film for the east side cover on solar transmission and thus the internal temperature rise was quantified. The building was simulated to house 30 pigs at a body weight of 70 kg. Resistive heating wire was used to simulate the sensible heat generation of the pigs at 131.5 W/pig at 10°C temperature.

The inside temperature averaged 6.9°C higher than the outside temperature during the minimum ventilation period. As the exhaust air passed through the double-layer air space, 25.4% of exhaust heat transferred back into the building and 74.6% lost to the outside. When replacing the reflective covers with the PVC film covers on the east side, the internal temperature rise increased to an average of 7.6°C with a maximum of 12.7°C. The magnitude of temperature rise was proportional to the transmitted solar radiation, as evidenced by the higher temperature rise during the day and significantly reduced temperature rise at night. To eliminate the effects of cold, nocturnal radiation, the PVC film cover should be covered by the regular reflective cover at night. One-holed air duct had a tendency to produce drafts in the pig occupied zone (POZ, 1.2 × 0.7 m), whereas four-holed air duct tended to have less mixing effects on the air. In comparison, the combination of two-holed air duct and use of the internal curtain was found to be the best in achieving warmer air temperature and minimizing drafts in POZ.

Comments

This article is from Transactions of the ASABE 40, no. 4 (1997): 1171–1177.

Description
Keywords
Citation
DOI
Source
Copyright
Wed Jan 01 00:00:00 UTC 1997
Collections