Effect of Perforated Plate Open Area on Gas Holdup in Rayon Fiber Suspensions

Thumbnail Image
Date
2005-04-14
Authors
Su, Xuefeng
Heindel, Theodore
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Heindel, Theodore
University Professor
Research Projects
Organizational Units
Organizational Unit
Mechanical Engineering
The Department of Mechanical Engineering at Iowa State University is where innovation thrives and the impossible is made possible. This is where your passion for problem-solving and hands-on learning can make a real difference in our world. Whether you’re helping improve the environment, creating safer automobiles, or advancing medical technologies, and athletic performance, the Department of Mechanical Engineering gives you the tools and talent to blaze your own trail to an amazing career.
Journal Issue
Is Version Of
Versions
Series
Department
Mechanical Engineering
Abstract

Three different aeration plates are used to study their effect on gas holdup and flow regime transition in fiber suspensions. The aeration plates differ by their open-area ratios (A=0.57%, 0.99%, and 2.14%), where the hole diameter remains the same while the number of holes increase. Experiments are performed using three different Rayon fiber lengths (L=3, 6, and 12mm) over a range of superficial gas velocities (Ug⩽18cm/s) and fiber mass fractions (0⩽C⩽1.8%) in a 15.24cm dia semi-batch bubble column. Experimental results show that the aeration plate with A=0.99% produces the highest gas holdup in an air-water system and low fiber mass fraction suspensions, and the plate with A=2.14% yields the lowest gas holdup in these systems. In medium fiber mass fraction suspensions, the plate with A=0.57% produces slightly higher gas holdup values, while the other two plates yield similar results. The effect of the aeration plate open area on gas holdup diminishes at high fiber mass fractions (C⩾1.2%). All aeration plates generate homogeneous, transitional, and heterogeneous flow regimes over the range of superficial gas velocities for air-water and low fiber mass fraction suspensions. However, the aeration plate with A=2.14% enhances the flow regime transition, i.e., the superficial gas velocity at which transitional flow appears is lower. Additionally, the fiber mass fraction at which pure heterogeneous flow is observed is lower when A=2.14%.

Comments

This article is from Journal of Fluids Engineering 12 (2005): 816–823, doi:10.1115/1.1994878. Posted with permission.

Description
Keywords
Citation
DOI
Copyright
Sat Jan 01 00:00:00 UTC 2005
Collections