Generating tap test images with a free-hand motorized tapper

Thumbnail Image
Date
2008-07-01
Authors
Barnard, Daniel
Foreman, Cory
Hsu, David
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Research Projects
Organizational Units
Organizational Unit
Center for Nondestructive Evaluation

The Center for Nondestructive Evaluation at Iowa State has been involved in the use of nondestructive evaluation testing (NDT) technologies to: assess the integrity of a substance, material or structure; assess the criticality of any flaws, and to predict the object’s remaining serviceability. NDT technologies used include ultrasonics and acoustic emissions, electromagnetic technologies, computer tomography, thermal imaging, and others.

History
In October of 1985 the CNDE was approved by the State Board of Regents after it had received a grant from the National Science Foundation (NSF) as an Industry/University Cooperative Research Center.

Journal Issue
Is Version Of
Versions
Series
Department
Center for Nondestructive Evaluation
Abstract

Previously we have described the Computer Aided Tap Tester (CATT), a simple instrumented probe and software that facilitates the generation of tap test C‐scans in field environments. Early in the CATT development it was noted that inspectors prefer hand tapping at random locations over the part, eventually covering the part to the satisfaction of the inspector. To speed inspections, a regimented method of tapping was incorporated into the CATT via a grid laid over the part. Although the CATT system is quite simple to use, the method of tapping at each grid location in a pre‐determined raster pattern continues to encounter resistance from the inspectors. The preferred free scanning of the inspection area dovetails nicely with the GenScan system previously reported on, where the operator scans over the inspection area freely, starting with larger pixels, and refines the geometry of flaw indications with finer pixels. As part of an Air Force project, we are merging the CATT instrumented tap data with position encoding and pixel change on‐the‐fly features of the GenScan. A description and demonstration of its operation will be presented. This material is based on work supported by the Air Force Research Laboratory under Contract#FA8650‐04‐C‐5228 at Iowa State University’s Center for NDE.