A contact formulation based on a volumetric potential: Application to isogeometric simulations of atrioventricular valves

Thumbnail Image
Date
2018-03-01
Authors
Kamensky, David
Xue, Fei
Lee, Chung-Hao
Yan, Jinhui
Bazilevs, Yuri
Hsu, Ming-Chen
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Hsu, Ming-Chen
Associate Professor
Research Projects
Organizational Units
Organizational Unit
Mechanical Engineering
The Department of Mechanical Engineering at Iowa State University is where innovation thrives and the impossible is made possible. This is where your passion for problem-solving and hands-on learning can make a real difference in our world. Whether you’re helping improve the environment, creating safer automobiles, or advancing medical technologies, and athletic performance, the Department of Mechanical Engineering gives you the tools and talent to blaze your own trail to an amazing career.
Journal Issue
Is Version Of
Versions
Series
Department
Mechanical Engineering
Abstract

This work formulates frictionless contact between solid bodies in terms of a repulsive potential energy term and illustrates how numerical integration of the resulting forces is computationally similar to the “pinball algorithm” proposed and studied by Belytschko and collaborators in the 1990s. We thereby arrive at a numerical approach that has both the theoretical advantages of a potential-based formulation and the algorithmic simplicity, computational efficiency, and geometrical versatility of pinball contact. The singular nature of the contact potential requires a specialized nonlinear solver and an adaptive time stepping scheme to ensure reliable convergence of implicit dynamic calculations. We illustrate the effectiveness of this numerical method by simulating several benchmark problems and the structural mechanics of the right atrioventricular (tricuspid) heart valve. Atrioventricular valve closure involves contact between every combination of shell surfaces, edges of shells, and cables, but our formulation handles all contact scenarios in a unified manner. We take advantage of this versatility to demonstrate the effects of chordal rupture on tricuspid valve coaptation behavior.

Comments

This is a manuscript of an article published as Kamensky, David, Fei Xu, Chung-Hao Lee, Jinhui Yan, Yuri Bazilevs, and Ming-Chen Hsu. "A contact formulation based on a volumetric potential: Application to isogeometric simulations of atrioventricular valves." Computer Methods in Applied Mechanics and Engineering 330 (2018): 522-546. DOI: 10.1016/j.cma.2017.11.007. Posted with permission.

Description
Keywords
Citation
DOI
Copyright
Sun Jan 01 00:00:00 UTC 2017
Collections