2008 ultrasonic benchmark studies of interface curvature—a summary

Thumbnail Image
Date
2008-07-01
Authors
Schmerr, Lester
Huang, Ruiju
Raillon, R.
Mahaut, S.
Leymarie, N.
Lonne, S.
Song, S.-J.
Kim, H.-J.
Spies, M.
Lupien, V.
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Research Projects
Organizational Units
Journal Issue
Is Version Of
Versions
Series
Department
Center for Nondestructive Evaluation
Abstract

In the 2008 QNDE ultrasonic benchmark session researchers from five different institutions around the world examined the influence that the curvature of a cylindrical fluid‐solid interface has on the measured NDE immersion pulse‐echo response of a flat‐bottom hole (FBH) reflector. This was a repeat of a study conducted in the 2007 benchmark to try to determine the sources of differences seen in 2007 between model‐based predictions and experiments. Here, we will summarize the results obtained in 2008 and analyze the model‐based results and the experiments.

Comments

Copyright 2009 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.

This article appeared in AIP Conference Proceedings, 1096 (2009): 1973–1979 and may be found at: http://dx.doi.org/10.1063/1.3114202.

Description
Keywords
Citation
DOI
Source
Copyright
Thu Jan 01 00:00:00 UTC 2009