Description

The RFC/NDE System comprises automated eddy current and ultrasonic inspection stations developed by Systems Research Laboratories for Air Force depot level inspections of aircraft engines. The system performance is being evaluated through a series of experiments whose objectives are to quantify crack detection capability as a function of crack size in various engine components. This paper presents the eddy current results from the first (preliminary) phase of this evaluation.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

6A

Chapter

Chapter 5: NDE Systems and Reliability

Section

System Reliability

Pages

987-994

DOI

10.1007/978-1-4613-1893-4_113

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

Analysis of the RFC/NDE System Performance Evaluation Experiments

La Jolla, CA

The RFC/NDE System comprises automated eddy current and ultrasonic inspection stations developed by Systems Research Laboratories for Air Force depot level inspections of aircraft engines. The system performance is being evaluated through a series of experiments whose objectives are to quantify crack detection capability as a function of crack size in various engine components. This paper presents the eddy current results from the first (preliminary) phase of this evaluation.