Description

The evaluation of the RFC/NDE System has produced capability characteristics in the format of â vs. a or apparent cracksize vs. actual cracksize. Although crack sizing has long been a major concern of NDE practitioners and theoreticians, the analysis procedure which permits straightforward conversion of these â vs. a to POD vs. a, or Probability of Detection vs. cracksize, is a recent development [1]. This paper will compare these two descriptions of NDE system capability by comparing their influence on the Retirement for Cause (RFC) process.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

6A

Chapter

Chapter 5: NDE Systems and Reliability

Section

System Reliability

Pages

995-1002

DOI

10.1007/978-1-4613-1893-4_114

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

Application of the RFC/NDE System Testing Results

La Jolla, CA

The evaluation of the RFC/NDE System has produced capability characteristics in the format of â vs. a or apparent cracksize vs. actual cracksize. Although crack sizing has long been a major concern of NDE practitioners and theoreticians, the analysis procedure which permits straightforward conversion of these â vs. a to POD vs. a, or Probability of Detection vs. cracksize, is a recent development [1]. This paper will compare these two descriptions of NDE system capability by comparing their influence on the Retirement for Cause (RFC) process.