For PWR power plants, the steam generator (SG) provides a dynamic link between the reactor and the turbine generator. A steam generator typically consists of Inconel tubes anchored at intervals with stainless steel support plates. The primary coolant from the nuclear reactor circulates through these tubes. Heat, transferred to the secondary coolant by conduction through the tube wall, generating steam which is used for running the turbine.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

9A

Chapter

Chapter 3: Interpretive Signal and Image Processing

Section

A: Signal Processing and Neural Networks

Pages

697-704

DOI

10.1007/978-1-4684-5772-8_87

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

A Simple Algorithm of Mixing Technique of Digital Eddy Current Signals for Steam Generator Tubes

Brunswick, ME

For PWR power plants, the steam generator (SG) provides a dynamic link between the reactor and the turbine generator. A steam generator typically consists of Inconel tubes anchored at intervals with stainless steel support plates. The primary coolant from the nuclear reactor circulates through these tubes. Heat, transferred to the secondary coolant by conduction through the tube wall, generating steam which is used for running the turbine.