Interface quality between layers in a layered structure is critical in fracture and fatigue analysis. A theoretical and quantitative solution to the problem from a NDE point of view would be desirable in both manufacturing and for in-service investigation of a variety of different structures. For example a great need exists to develop a reliable and efficient inspection program of adhesive bond delamination and interfacial weakness detection in aging aircraft noting that the bond degradation generally preceeds cracking in the aluminum skin, starting at the rivet holes.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

12B

Chapter

Chapter 5: Engineered Materials

Section

Bonded Joints

Pages

1579-1585

DOI

10.1007/978-1-4615-2848-7_201

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

Lamb Wave Mode Selection for Increased Sensitivity ot Interfacial Weaknesses of Adhesive Bonds

La Jolla, CA

Interface quality between layers in a layered structure is critical in fracture and fatigue analysis. A theoretical and quantitative solution to the problem from a NDE point of view would be desirable in both manufacturing and for in-service investigation of a variety of different structures. For example a great need exists to develop a reliable and efficient inspection program of adhesive bond delamination and interfacial weakness detection in aging aircraft noting that the bond degradation generally preceeds cracking in the aluminum skin, starting at the rivet holes.