Location

Seattle, WA

Start Date

1-1-1996 12:00 AM

Description

Eddy current examination was selected as the industrial method to be used for the inspection of PWR steam generator tubes because of both physical and operational advantages.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

15B

Chapter

Chapter 8: Systems, New Techniques and Process Control

Section

Systems

Pages

1903-1908

DOI

10.1007/978-1-4613-0383-1_249

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

High Performance Ultrasonic Inspection of Tubes

Seattle, WA

Eddy current examination was selected as the industrial method to be used for the inspection of PWR steam generator tubes because of both physical and operational advantages.