Ultrasonic measurements performed with a pair of acoustic transducers in pitch-catch mode are of common use in the NDE field. In particular, for nearfield leaky wave (LW) measurements which are directed at precise determination of material properties of layered elastic structure in immersion. In LW measurements, the acoustic transducer beams are aligned at angles so as to phase match to one or several of the structure’s leaky (Rayleigh or Lamb) waves. The amplitude and phase of the scattered acoustic energy collected, and converted to an electrical voltage, by the phase-sensitive receiving transducer depends not only on the properties of the structure but also on the parameters of the transducers used, in particular, their apertures and alignment angles. Transducer alignment issues are especially important for transducers that radiate or receive over a narrow angular range.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

17A

Chapter

Chapter 4: NDE Sensors and Fields

Section

UT Sensors, Transducers and Fields

Pages

947-954

DOI

10.1007/978-1-4615-5339-7_122

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

Forward Modeling of Transducer Misalignment Effects in Ultrasonic Leaky Wave Measurements

La Jolla, CA

Ultrasonic measurements performed with a pair of acoustic transducers in pitch-catch mode are of common use in the NDE field. In particular, for nearfield leaky wave (LW) measurements which are directed at precise determination of material properties of layered elastic structure in immersion. In LW measurements, the acoustic transducer beams are aligned at angles so as to phase match to one or several of the structure’s leaky (Rayleigh or Lamb) waves. The amplitude and phase of the scattered acoustic energy collected, and converted to an electrical voltage, by the phase-sensitive receiving transducer depends not only on the properties of the structure but also on the parameters of the transducers used, in particular, their apertures and alignment angles. Transducer alignment issues are especially important for transducers that radiate or receive over a narrow angular range.