Description

Spall damage or fracture is caused by intensive tensile stress pulse within a solid which has been impacted by a high velocity projectile. This damage, microvoids or microcracks distributed within thin layer of the solid, are usually evaluated by destructive means, that is, cutting the samples and observation by SEM or an optical microscope [1–3]. This method requires laborious works. Essentially, with such destructive means we can not monitor the spall damage evolution under repeated impacts on single sample.

Book Title

Review of Progress in Quantitative Nondestructive Evaluation

Volume

17B

Chapter

Chapter 6: Materials Characterization

Section

Materials Properties

Pages

1517-1522

DOI

10.1007/978-1-4615-5339-7_196

Language

en

File Format

application/pdf

Share

COinS
 
Jan 1st, 12:00 AM

Ultrasonic Imaging of Spall Damage Under Repeated Plate Impact Tests with C-Scan Acoustic Microscope

La Jolla, CA

Spall damage or fracture is caused by intensive tensile stress pulse within a solid which has been impacted by a high velocity projectile. This damage, microvoids or microcracks distributed within thin layer of the solid, are usually evaluated by destructive means, that is, cutting the samples and observation by SEM or an optical microscope [1–3]. This method requires laborious works. Essentially, with such destructive means we can not monitor the spall damage evolution under repeated impacts on single sample.