Photography-based method for assessing fluorescein clearance test in dogs

Thumbnail Image
Supplemental Files
Date
2018-09-03
Authors
Pontes Oriá, Arianne
Flores Rebouças, Miriam
Martins Filho, Emanoel
de Assis Dórea Neto, Francisco
Raposo, Ana Cláudia
Sebbag, Lionel
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Research Projects
Organizational Units
Organizational Unit
Veterinary Clinical Sciences
The mission of the Veterinary Clinical Sciences Department and the Veterinary Medical Center is to be strong academically, to provide outstanding services, and to conduct research in the multiple areas of Veterinary Clinical Sciences. Our goals are to teach students in the multiple disciplines of Veterinary Clinical Sciences, to provide excellent veterinary services to clients, and to generate and disseminate new knowledge in the areas of Veterinary Clinical Sciences. Our objectives are to provide a curriculum in the various aspects of Veterinary Clinical Sciences which ensures students acquire the skills and knowledge to be successful in their chosen careers. We also strive to maintain a caseload of sufficient size and diversity which insures a broad clinical experience for students, residents, and faculty. In addition, we aim to provide clinical veterinary services of the highest standards to animal owners and to referring veterinarians. And finally, we strive to provide an environment and opportunities which foster and encourage the generation and dissemination of new knowledge in many of the disciplines of Veterinary Clinical Sciences.
Journal Issue
Is Version Of
Versions
Series
Department
Veterinary Clinical Sciences
Abstract

Background: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface.

Methods: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 μL) or 2 drops (70 μL) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility).

Results: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation ≤2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post- fluorescein instillation in the 2 drops vs. 1 drop groups (p ≤ 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively.

Conclusions: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.

Comments

This article is published as Oriá, Arianne Pontes, Miriam Flores Rebouças, Emanoel Martins Filho, Francisco de Assis Dórea Neto, Ana Cláudia Raposo, and Lionel Sebbag. "Photography-based method for assessing fluorescein clearance test in dogs." BMC Veterinary Research 14, no. 1 (2018): 269. DOI: 10.1186/s12917-018-1593-y. Posted with permission.

Description
Keywords
Citation
DOI
Copyright
Mon Jan 01 00:00:00 UTC 2018
Collections